Power out in one room? Here's the fault tree we work.
When the rest of the house is humming along but one room is dark, the problem is almost always sitting on a single final subcircuit between your switchboard and the affected GPOs or lights. We get this call from Figtree, Corrimal, Fairy Meadow, Berkeley and Port Kembla nearly every week. Here's how we diagnose it, in the order we actually do it.
The four most common causes - in the order we check them.
1. Tripped RCD or circuit breaker.
On any home built or rewired in the last fifteen years, we start at the switchboard. We look for an RCD or RCBO in the mid-position (not fully off, not fully on), a breaker that's clearly tripped, or a neutral bar with a loose connection. Most single-room outages on newer Illawarra estates are exactly this - usually triggered by a failing appliance like an old kettle, a damaged extension lead, or moisture in an outdoor GPO after a southerly blows rain in off the escarpment. We isolate the circuit, test it cold, and only then think about replacing protection.
2. A failed GPO, switch or light fitting.
The next layer is the accessory itself. Power points get hammered over twenty years - heaters and air-con plugs in particular cook the terminations. We pull the suspect GPO, check the back of it for discolouration, burnt insulation, loose screws or a cracked block. In older Wollongong CBD weatherboards a dead room often comes down to a single GPO with a charred terminal, often the one behind the lounge that has had an oil column heater on it every winter for fifteen years.
3. Cable damage between the board and the room.
If the protection is good and the accessories test clean, we go looking for the cable. In Illawarra roof spaces this is often rodent damage, especially in homes within a block of bushland or the escarpment. We also see nail and screw strikes where a homeowner has hung something heavy without a stud finder. On older Port Kembla and Cringila homes, ageing TPS cable insulation can be brittle enough that an attic crawl during an earlier reno cracked it. We use insulation-resistance testing (megger) to find the fault location rather than guessing.
4. A failed neutral on a shared circuit.
The rarest of the four, but the one that catches inexperienced sparkies. On older homes with shared neutrals across two circuits, a failed neutral can produce half-voltage at GPOs (so a fridge light is dim but won't run), or a circuit that measures live but won't deliver any current under load. We test for this with a clamp meter under load - not just a multimeter on an unloaded circuit, which will read perfectly fine and send you home thinking it's solved.
Why we don't lead with the switchboard on a 2010-era estate.
On a Horsley, Albion Park or Shellharbour estate from the mid-2000s onward, the switchboard is already to a modern spec - split RCDs, properly rated breakers, decent labelling. Starting there wastes an hour. The fault is far more likely to be at the point of use. On a pre-2000 Wollongong CBD or Corrimal cottage with a ceramic-fuse board, that calculus flips and we start at the board because the protection itself is often the weak link and the wiring downstream may need a full safety inspection too.
Quick questions, fast answers.
Is it safe to keep using the rest of the house?
Yes, in most single-circuit faults. The other circuits are independently protected at the board. The exception: if you smell hot plastic, see scorching around a GPO, or hear buzzing at the switchboard, isolate the main switch and call us straight away - that's a job for our emergency electrical service, not a next-day diagnosis.
Does Endeavour Energy need to be involved?
Almost never on a single-room fault. Endeavour's responsibility stops at the point of attachment / meter. Anything inside your home is on the homeowner's side and is our work. The exception is if the supply itself is flickering across the whole street, in which case the report goes to Endeavour first.
Will this need a switchboard upgrade?
Sometimes - particularly if the diagnosis reveals you have no RCD coverage at all on power circuits, or the board is the old ceramic-fuse type. AS/NZS 3000 requires RCD protection on every final subcircuit when a board is replaced. If we recommend an upgrade, you'll get a separate written quote; we don't roll one into a fault-find call without telling you.
Do you carry parts on the truck?
Standard GPOs, light switches, RCBOs, common breaker amperages, junction-box accessories and a small range of light fittings - yes. Speciality items (some smart switches, designer LED drivers, three-phase RCBOs for larger homes) we'll source the same day where possible, otherwise next business day.
More questions about a dead room.
-
Why is only one room without power when the rest of the house is fine?
It almost always means a single final subcircuit has either tripped at the switchboard or has a hard fault on the wiring between the board and the room. The mains supply from Endeavour Energy is obviously still good - the lights in the kitchen are on - so the fault is on your side of the meter. The four common causes are a tripped RCD or circuit breaker (often kicked by a faulty appliance), a loose connection in a power point or junction box, a damaged cable (rodent damage in roof spaces around Figtree and Corrimal is more common than people think), or a failed neutral on a shared circuit. We test in that order.
-
Should I just keep resetting the safety switch?
No. If an RCD trips, resets, and trips again within seconds or minutes, leave it off and unplug everything in the dead room. Reset it once with nothing plugged in - if it holds, plug appliances back in one at a time. If it trips with everything unplugged, the fault is in the fixed wiring (cable, GPO or light fitting) and that's an electrician's job. Repeatedly forcing an RCD on past a real fault defeats the safety device that's the whole reason it's there under AS/NZS 3000.
-
Could the problem be at the switchboard rather than the room?
It can, but on a 2010-era estate home in Horsley, Berkeley or Shellharbour it usually isn't where we start. Those boards are typically already split across multiple RCDs/RCBOs with reasonably modern breakers. The lower-cost, faster diagnosis is to confirm the breaker state at the board, then walk straight to the dead room and test the GPOs and light circuit. On older Wollongong CBD or Port Kembla homes - pre-2000, original ceramic-fuse boards - we do look at the board earlier because shared neutrals and undersized circuits are far more common.
-
How long does the diagnosis usually take, and what does it cost?
Most single-circuit faults are found and fixed inside an hour, sometimes two if we need to track a cable run through a roof space or under a deck. Standard daytime call-out plus first hour sits around $180-$240 in 2026, and most fixes (a failed GPO, a burnt termination, a faulty light switch) are wrapped up inside the first labour block. We give a firm written price before any major work - for example, if we have to chase a cable, fish a new run, or replace a section of damaged wiring.
-
What should I check myself before calling an electrician?
Three quick checks. First, look at the switchboard and see if anything is in the off or middle position - RCDs and breakers don't always look obviously tripped. Second, unplug everything in the affected room, then try the reset. Third, test a known-good appliance like a lamp in every GPO in the room - if one GPO is dead but others on the same wall work, the fault has narrowed to a single point. Tell us what you found when you call; it saves diagnostic time and we can usually quote tighter.